Issue 4.0
SV9100 Programming Manual 2-837
Description
Use Program 90-11 : System Alarm Report to define the details of the system alarm report.
Program 90 : Maintenance Program
90-11 : System Alarm Report
Level:
IN
Input Data
Item
No.
Item Input Data Default
02
Report Method
When alarm reports are e-mailed, set this option
to 1. E-mail address set in PRG 90-11-08.
0 = No Report
1 = E-mail Address
0
04
--- Not Used ---
06
SMTP Host Name
When alarm reports are e-mailed, set the SMTP
name (ex: smtp.yourisp.com). Contact your ISP
(Internet service provider) for the correct entry if
needed.
Up to 255 Characters
No Setting
07
SMTP Host Port Number
When alarm reports are e-mailed, set the SMTP
host port number. Contact your ISP (Internet
service provider) for the correct entry if needed.
0~65535
25
08
To E-mail Address
When alarm reports are e-mailed, set this e-mail
address to where the report should be sent.
Up to 255 Characters
No Setting
09
Reply Address
When alarm reports are e-mailed, set the e-mail
address where replies should be e-mailed.
Up to 255 Characters
No Setting
10
From Address
When alarm reports are e-mailed, set this e-mail
address for the station sending the report.
Up to 255 Characters
No Setting
11
DNS Primary Address
When alarm reports are e-mailed, set the DNS
primary address.
0.0.0.0~255.255.255.255
0.0.0.0
12
DNS Secondary Address
When alarm reports are e-mailed, set the DNS
secondary address.
0.0.0.0~255.255.255.255
0.0.0.0