EasyManua.ls Logo

NEC Univerge SV9100 - IP Trunk Data Setup

NEC Univerge SV9100
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 4.0
2-180 Program 14 : Trunk, Basic Setup
Description
Use Program 14-18 : IP Trunk Data Setup to define the basic setting of each IP Trunk.
Program 14 : Trunk, Basic Setup
14-18 : IP Trunk Data Setup
Level:
IN
Input Data
Trunk Port Number 001~400
Item
No.
Item Input Data Default
01
IP Trunk Type
This indicates the IP Trunk type. (Read
Only)
0 = None
1 = SIP
2 = H.323
3 = CCIS
0
02
System ID (SIP Trunk)
This indicates NetLink System ID of the
trunk when multiple SIP trunks for
NetLink is enabled. (Read Only)
0 ~ 50
0
03
P2P Mode (SIP Trunk)
Select whether or not peer-to-peer
connection method is used for the SIP
Trunk.
0 = Disable
1 = Enable
0
04
Video Mode (SIP Trunk)
Select whether or not the Video mode is
used for the SIP Trunk.
0 = Disable
1 = Enable
0
05
SIP Profile
1 = Profile 1
2 = Profile 2
3 = Profile 3
4 = Profile 4
5 = Profile 5
6 = Profile 6
With Version 2000
or lower CPU
Software only two
SIP Profiles are
supported.
1

Table of Contents