Issue 4.0
2-732 Program 82 : Basic Hardware Setup for Extension
Description
Use Program 82-04 : LCA Initial Data Setup to set the basic data of the LCA.
Program 82 : Basic Hardware Setup for Extension
82-04 : LCA Initial Data Setup
Level:
MF
Input Data
Item
No.
Item Input Data Default
01
Companding Method Type
0 = -law
1 = A-law
0
02
Ringing Frequency
0 = 25Hz
1 = 20Hz
2 = 16Hz
1 (20Hz)
03
Minimum Break Time
1~255 (5ms~1275ms)
2 (10ms)
04
Maximum Break Time
1~255 (5ms~1275ms)
20(100ms)
05
Minimum Make Time
1~255 (5ms~1275ms)
2 (10ms)
06
Maximum Make Time
1~255 (5ms~1275ms)
20 (100ms)
07
Minimum Hook Flash Time
1~255 (5ms~1275ms)
21 (105ms)
08
Maximum Hook Flash Time
1~255 (5ms~1275ms)
200 (1000ms)
09
Minimum Ground Flash Time
1~255 (5ms~1275ms)
21 (105ms)
10
Minimum Off-Hook Time
1~255 (5ms~1275ms)
21 (105ms)
11
No Detection Time after Off-Hook
1~255 (5ms~1275ms)
60 (300ms)
12
No Detection Time after Pulse Dial
Detection
1~255 (5ms~1275ms)
70 (350ms)
13
Loop Disconnect Time, Reversal
Time
1~255 (10ms~2550ms)
60 (600ms)
14
Ring, Message Wait Period Time
1~255 (5ms~1275ms)
150 (750ms)