SV9100 Programming Manual 2-673
Program: 80
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is
defined by the combination of 32 Basic Tones.
Program 80 : Basic Hardware Setup for System
80-01 : Service Tone Setup
Level:
IN
Input Data
Service Tone Number 01~64
Item
No.
Item Input Data
01
Repeat Count
0~255 (0 = until On-Hook)
Unit Number 1~8
Item
No.
Item Input Data
02
Basic Tone Number
1~33
(0 = No Tone)
(33 = Default Time Slot)
03
Duration Count
1~255 (100~25500ms)
04
Gain Level (dB)
1~57 (-15.5 ~ +12.5)