Description
Use Program 80-07 : Call Progress Tone Detector Frequency Setup to set the frequency of the
detection tone set with Program 80-04-12 and Program 80-04-13.
Conditions
None
Feature Cross Reference
None
Program 80 : Basic Hardware Setup for System
80-07 : Call Progress Tone Detector Frequency Setup
Level:
MF
Input Data
Frequency
Table No.
Input Data Default
1
0, 10~255
(100~2550 Hz)
(0 = Not used)
35 (350 Hz)
2 44 (440 Hz)
3 48 (480 Hz)
4 62 (620 Hz)
5110