Description
Use Program 20-17 : Operator Extension to designate an operator. When an extension user dials 0 or
9 (defined by Program 11-01 Type 5), calls go to the operator selected in this program.
If you do not assign an extension in Program 90-11-01, system alarms appear on the extension assigned
in this option.
Conditions
None
Feature Cross Reference
Intercom
Program 20 : System Option Setup
20-17 : Operator Extension
Level:
IN
Input Data
Operator Number 1~8
Item
No.
Item Input Data Default
Related
Program
01
Operators Extension Number
Define the extension numbers to be used
by operators.
Up to eight digits
101 11-01
20-01-01