SV9100 Programming Manual 2-755
Description
Use Program 84-06 : PVA Data Setting to set up threshold levels of every CD-PVAA slot.
Conditions
System programming must be exited before these program options take affect.
Feature Cross Reference
Voice Over Internet Protocol (VoIP)
Program 84 : Hardware Setup for VoIP
84-06 : PVA Data Setting
Level:
IN
Input Data
Slot Number 01~24
Item
No.
Item Input Data Default Description
01
RTP Port Number
0~65534
10020
02
RTCP Port Number
RTP Port Number + 1
10021
It has to be RTP Port Number + 1.
04
Fract Lost Threshold
0~100%
0
The data is sent to the GCD-CP10 if the
value exceeds the defined value.
05
Packets Lost Threshold
0~16777215
0
The data is sent to the GCD-CP10 if the
value exceeds the defined value.
07
Jitter Threshold
0~4294967295 (sec)
0
The data is sent to the GCD-CP10 if the
value exceeds the defined value.
09
Delay LSR Threshold
0~4294967295 (sec)
0
The data is sent to the GCD-CP10 if the
value exceeds the defined value.
16
IMCP Redirect
0=No
1=Yes
0
The VOIP blade supports sending the
Internet Message Control Protocol
(IMCP) redirect message.