SV9100 Programming Manual 2-307
Description
Use Program 20-38 : Operator Group Setting to set up priority of a call when calling an operator
telephone.
Conditions
None
Feature Cross Reference
None
Program 20 : System Option Setup
20-38 : Operator Group Setting
Level:
IN
Input Data
Operator Group 1~15
Item
No.
Item Input Data Default
01
Operator Access Mode
Assign if the operator is called, starting with the first
operator, every time (0) or a different operator is tried
first (1).
0 = Step
1 = Circular
0