Issue 4.0
SV9100 Programming Manual 2-295
Description
Use Program 20-28 : Trunk to Trunk Conversation to define system options for Trunk to Trunk
Conversation.
Conditions
None
Feature Cross Reference
None
Program 20 : System Option Setup
20-28 : Trunk to Trunk Conversation
Level:
IN
Input Data
Item
No.
Item Input Data Default
Related
Programming
01
Conversation Continue Code
Input the code that can be dialed
to continue the conversation after
the Trunk-to-Trunk Release
Warning Tone is heard.
0~9, #,
(Set for one digit only)
No Setting 14-01-25
20-28-03
24-02-07
24-02-10
25-07-07
25-07-08
02
Conversation Disconnect Code
Input the code that can be dialed
to disconnect the conversation
after the Trunk-to-Trunk Release
Warning Tone is heard.
0~9, #,
(Set for one digit only)
No Setting 14-01-25
24-02-07
24-02-10
25-07-07
25-07-08
03
Conversation Continue Time
Input the time the conversation
extends when the Conversation
Continue Code is dialed.
0~64800 seconds
0 14-01-25
20-28-01
24-02-07
24-02-10
25-07-07
25-07-08

Table of Contents