EasyManua.ls Logo

NEC Univerge SV9100 - Program 34: Tie Line Setup; E&M Tie Line Basic Setup

NEC Univerge SV9100
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SV9100 Programming Manual 2-473
Program: 34
Description
Use Program 34-01 : E&M Tie Line Basic Setup to define the basic settings for eac h E&M Tie line.
Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
Level:
IN
Input Data
Trunk Port Number 001~400
Item
No.
Item Input Data Default Description
Related
Program
01
DID/E&M Start
Signaling
0 = 2nd Dial Tone
1 = Wink
2 = Immediate
3 = Delay
1
Set the start signaling mode for
DID and Tie trunks. DID and
Tie trunks can use either
immediate start or wink start
signaling.
22-02
02
Receive Dial Type
for E&M Tie Line
0 = DP
1 = DTMF
2 = MF
1 10-09
03
E&M Dial-In Mode
0 = Specify Extension
Number (Intercom)
1 = Use Conversion
Table (NTT)
0
Determine if the incoming Tie
Line call should be directed as
an intercom call or if it should
follow the DID Translation
Table in Program 22-11.
22-11
04
E&M Line Dial Tone
0 = Disable (No)
1 = Enable (Yes)
1
Enter 1 if the Tie Line should
send dial tone to the calling
system after the call is set up.
Enter 0 if the Tie Line should
not send dial tone.
05
System Toll
Restriction
0 = System
1 = Each extension
0
Determine if an incoming Tie
Line call should be subject to
Toll Restriction.
21-05