Issue 4.0
2-404 Program 25 : VRS/DISA Setup
Description
Use Program 25-02 : DID/DISA VRS Message to assign the VRS message number to be used as the
Automated Attendant Message for each trunk which is assigned as a VRS/DISA.
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
Program 25 : VRS/DISA Setup
25-02 : DID/DISA VRS Message
Level:
IN
Input Data
Trunk Port Number 001~400
Item
No.
Day/
Night
Mode
Message (Talkie)
Source
Additional Data Default
01 1~8
0 = No Message
1 = VRS
2 = ACI
3 = Department
Group
1 = 01~100 (VRS Message Number)
2 = 01~04 (ACI Group Number)
3 = 01~64 (Extension Group Number)
0