Issue 4.0
2-234 Program 15 : Extension, Basic Setup
Description
Use Program 15-24 : Registration of Standard SIP Terminal to register data in the standard SIP
terminal where Register is not used.
Program 15 : Extension, Basic Setup
15-24 : Registration of Standard SIP Terminal
Level:
IN
Input Data
Extension Number 001 ~ 960
Input Data
Item
No.
Item Input Data Default
01
Using IP Address
IP Address of the standard SIP
terminal that is used as the SIP
extension. When Program 15-24-03 is
set to 1, this Program cannot be
changed from 0.0.0.0 (except using
PCProgramming).
0.0.0.0~255.255.255.255
0.0.0.0
02
Call Procedure Port
Call procedure port of the standard
SIP terminal that is used as SIP
extension.
0~65535
5060
03
Registration Setting when
REGISTER isn’t used
Enables or disables the Registration
method. An error will occur if Program
15-24-01 is 0.0.0.0 and this Program
is set to 1 (except using
PCProgramming).
0 = Disable
1 = Enable
0
04
Transport Protocol
This program sets the transport
protocol for selected SIP terminal
without registration method.
0 = UDP
1 = TCP
0