Description
Use Program 21-06 : Toll Restriction Table Data Setup to set the system Toll Restriction data. Dial
1~9, 0,
, # can be entered in each table.
Program 21 : Outgoing Call Setup
21-06 : Toll Restriction Table Data Setup
Level:
IN
Input Data
Item
No.
Item Table Input Data Default Description
01
International Call
Restriction Table
1~10
Dial
(Up to four
digits)
Tables 1
~10 = No
Setting
Program the Restrict Table for
international calls. The system
has 10 International Call
Restrict Tables. Each entry
can have up to four digits.
02
International Call
Permit Code
Table
1~20
Dial
(Up to six digits)
Tables 1
~20 = No
Setting
Program the Permit Table for
international calls. The system
has 20 International Call
Permit Tables. Each entry can
have up to six digits.
03
Maximum
Number Digits
Table
Assignment
1~4
4~30
Tables 1
~ 4 = 30
Select the maximum number
of digits allowed in outgoing
calls for each table.
04
Common Permit
Code Table
1~10
Dial
(Up to four
digits)
Table 1 = 911
Table 2 = 1800
Table 3 = 1888
Table 4 = 1822
Table 5 = 1833
Table 6 = 1844
Table 7 = 1855
Table 8 = 1866
Table 9 = 1877
Table 10 = No Setting
Program the Common Permit
Code Table. This table
contains up to 10 codes you
commonly allow users to dial.
05
Common
Restriction Table
1~10
Dial
(Up to 12 digits)
Table 1 = 900
Table 2 = 1900
Table 3 = 976
Tables 4 ~ 10 = No
Setting
Program the Common Restrict
Code Table. This table
contains up to 10 codes you
commonly prevent users from
dialing.

Table of Contents