SV9100 Programming Manual 2-19
Description
Use Program 10-05 : General Purpose Relay Setup to define which Relay circuits (5~8) on PGD(2)-
U10 ADP are used for General Purpose Relay.
Input Data
Conditions
None
Feature Cross Reference
Analog Communications Interface (ACI)
Program 10 : System Configuration Setup
10-05 : General Purpose Relay Setup
Level:
IN
Input Data
General Purpose Relay No. 1~8
Item
No.
Item Input Data Default
01
Slot No.
Physical Port of DLCA Sensor Circuit No.
Slot No: 0~24
DLCA Port: 0~16
Relay No: 0, 5~8
After each entry,
press the Transfer Key
to advance to the next
entry.
0 - 0 - 0
02
Drive Timer Setup
0~64800
0 = No Setting
1 = 0.1s
2 = 0.2s
3 = 0.3s
:
10 = 1.0s
:
64800 = 6480s
0