Issue 4.0
2-302 Program 20 : System Option Setup
Description
Use Program 20-34: Remote Conference Group Setting to configure Remote Conference
parameters.
Program 20 : System Option Setup
20-34 : Remote Conference Group Setting
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
Remote Conference - Name
Set name for remote conference.
Up to 12 characters.
Default for conferences 1~4 = Conf 1-Conf 4
Default for conferences 5~20 = blank
02
Remote Conference - Password
Set password for remote conference.
Up to 4 numbers.
Default for conferences 1~4 = 1111
Default for conferences 5 ~20 = blank
03
Remote Conference - Maximum
Participants
Set the maximum number of allowed
participants for each conference.
0 ~ 32
Default for conferences 1~4 = 8
Default for conferences 5 ~20 = 0
04
Remote Conference - Maximum
Conference Duration
Set the time limit (in seconds) for
each conference.
0 ~ 64800sec
7200
05
Remote Conference - Ending
Conference Alert Tone Time
Set the time for the conference end
time alert tone to be played.
0 ~ 64800sec
300
06
Remote Conference - Password
Mode
Set whether users are prompted to
enter a password to access the
conference. Normal will prompt users
to enter a password. If set to Skip no
password is required to enter a
conference.
0 = Normal
1 = Skip
0
07
MCU Mode for Remote Conference
Set the MCU video mode for remote
conference. Mode 1 = CIF (352x288)
Mode 2 = VGA (640x480)
0 = Disable
1 = Mode 1
2 = Mode 2
0