Description
Use Program 21-04 : Toll Restriction Class for Extensions to assign a Toll Restriction class to an
extension. The details of Toll Restriction are defined in Program 21-05 and 21-06.
Conditions
None
Feature Cross Reference
None
Program 21 : Outgoing Call Setup
21-04 : Toll Restriction Class for Extensions
Level:
IN
NOTE
A telephone and a trunk have a Restriction Class. The higher class applies for outgoing
calls.
Input Data
Extension Number 001 ~ 960
Item
No.
Day/Night Mode
Restriction
Class
Default
Related
Program
01 1~9
9 = (Power Failure Mode)
1~15 2 14-01-08
21-05