Issue 4.0
SV9100 Programming Manual 2-163
38
Outgoing CLI Selection
Select CLI (Calling Party
Number) sending way to trunk.
When set to 0, extension CLI
number set in PRG21-13-01,
PRG21-18-01, or PRG21-19-01is
sent according to seized trunk
type (ISDN/H.323/SIP)
automatically.
When set to 1, calling extension
number is sent as CLI.
When set to 2, extension table
number set in PRG21-25-01 is
sent as CLI.
When set to 3, 4, or 5, extension
CLI number set in PRG21-13-01,
PRG21-18-01, or PRG21-19-01is
sent to seized trunk regardless of
trunk type.
0 = Contract Number
1 = Extension Number
2 = Extended Table
3 = PRG 21-13
4 = PRG 21-18
5 = PRG 21-19
6 = No digits
0 21-13-01
21-18-01
21-19-01
21-25-01
39
CLI Composition
If select default value 0:”prefer
extension”, the extension's CLI is
sent out, if it is not empty. If it is
empty, the trunk's CLI is sent
instead.
If select value 1:”combine trunk +
extension”, the trunk's CLI is
stored in the sending buffer,
padded with the extension's CLI.
0 = Prefer Extension
1 = Combine Trunk + Extension
0
40
ISDN Queue Announcement
Connect Mode
0 = Send CONNECT
1 = Send PROGRESS #8
0
22-14
22-15
41-11
41-19
41
Incoming Caller Name Usage
This setting determines whether
the caller name information from
the network is valid or not. If set
to 1 (Ignore), the caller name
information the network provides
is ignored.
0 = Use
1 = Ignore
0
46
Collect Call Blocking
Set the incoming ISDN collect
call block (reject) or not for the
trunk line.
0 = Disable
1 = Enable
0 20-09-09
47
DTMF Receiver Type
1 = Type 1
2 = Type 2
3 = Type 3
1
Item
No.
Item Input Data Default
Related
Program