Issue 4.0
2-14 Program 10 : System Configuration Setup
For DTI (T1) PKG Setup
Input Data
Physical Port Number 01~24
Item
No.
Item Input Data Default
01
Logical Port Number
The start port number of a T1 line is
displayed, and 24 logic ports are
automatically assigned to a DTI (T1)
line.
0~400
0
02
T1 Signal Format Selection
0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
1
03
Zero Code Suppression
0 = B8ZS
1 = AMI/ZCS
0
04
Line Length Selection
0 = 0 feet ~ 133 feet
1 = 133 feet ~ 266 feet
2 = 266 feet ~ 399 feet
3 = 399 feet ~ 533 feet
4 = 533 feet ~ 655 feet
0
05
T1 Clock Source
0 = Internal
1 = External
1
06
Number of Ports
0 = Auto
1 = 4 Ports
2 = 8 Ports
3 = 12 Ports
4 = 16 Ports
5 = 20 Ports
0
07
Straight/Cross Wiring
0 = Auto
1 = Manual (Cross)
2 = Manual (Straight)
0

Table of Contents