Issue 4.0
SV9100 Programming Manual 2-683
03
Min. Detect Level
0~15
Detect Level 0 : -10dBm(0) to -25dBm(15)
Detect Level 1 : -15dBm(0) to -30dBm(15)
Detect Level 2 : -20dBm(0) to -35dBm(15)
Detect Level 3 : -25dBm(0) to -40dBm(15)
Detect Level 4 : -30dBm(0) to -45dBm(15)
Detect Level 5 : -35dBm(0) to -50dBm(15)
Detect Level 6 : -40dBm(0) to -55dBm(15)
Detect Level 7 : -45dBm(0) to -60dBm(15)
Detect Level 8 : -50dBm(0) to -65dBm(15)
Detect Level 9 : -55dBm(0) to -70dBm(15)
Detect Level 10 : -60dBm(0) to -75dBm(15)
Detect Level 11 : -65dBm(0) to -80dBm(15)
Detect Level 12 : -70dBm(0) to -85dBm(15)
Detect Level 13 : -75dBm(0) to -90dBm(15)
Detect Level 14 : -80dBm(0) to -95dBm(15)
Detect Level 15 : -85dBm(0) to -100dBm(15)
04
Max. Detect Level
0~15
Detect Level 0 : 0dBm(0) to -15dBm(15)
Detect Level 1 : -5dBm(0) to -20dBm(15)
Detect Level 2 : -10dBm(0) to -25dBm(15)
Detect Level 3 : -15dBm(0) to -30dBm(15)
Detect Level 4 : -20dBm(0) to -35dBm(15)
Detect Level 5 : -25dBm(0) to -40dBm(15)
Detect Level 6 : -30dBm(0) to -45dBm(15)
Detect Level 7 : -35dBm(0) to -50dBm(15)
Detect Level 8 : -40dBm(0) to -55dBm(15)
Detect Level 9 : -45dBm(0) to -60dBm(15)
Detect Level 10 : -50dBm(0) to -65dBm(15)
Detect Level 11 : -55dBm(0) to -70dBm(15)
Detect Level 12 : -60dBm(0) to -75dBm(15)
Detect Level 13 : -65dBm(0) to -80dBm(15)
Detect Level 14 : -70dBm(0) to -85dBm(15)
Detect Level 15 : -75dBm(0) to -90dBm(15)
05
Forward Twist Level
0~9 (1dB ~ 10dB)
06
Backward Twist Level
0~9 (1dB ~ 10dB)
07
ON Detect Time
1~255 (15+ 15ms ~ 3825ms)
08
OFF Detect Time
1-255 (15+ 15ms ~ 3825ms)
10
Sensitivity Level
0-1
Item
No
Item Input Data