Issue 4.0
SV9100 Programming Manual 2-713
Conditions
None
Feature Cross Reference
None
71
Guard Time 1 (Ground)
1~255
(100ms ~ 25500ms)
9
900ms
72
Guard Time 1 (DID)
1~250
(4ms ~ 1000ms)
3
12ms
73
Guard Time 1 (E&M)
1~255
(100ms ~ 25500ms)
20
2000ms
74
Guard Time 1 (OPX)
1~255
(100ms ~ 25500ms)
40
4000ms
75
Guard Time 2 (ALL)
1~250
(4ms ~ 1000ms)
6
24ms
76
Dial Sending Complete Time
(ALL)
1~255
(100ms ~ 25500ms)
6
600ms
77
ON-HOOK bit Send Time (ALL)
1~255
(100ms ~ 25500ms)
6
600ms
78
Open Loop Time (Loop)
1~255
(100ms ~ 25500ms)
6
600ms
79
Open Loop Time (Ground)
1~255
(100ms ~ 25500ms)
6
600ms
80
Open Loop Time (DID)
1~250
(4ms ~ 1000ms)
13
52ms
81
Open Loop Time (E&M)
1~250
(4ms ~ 1000ms)
13
52ms
82
Open Loop Time (OPX)
1~250
(4ms ~ 1000ms)
13
52ms
Input Data (Continued)