EasyManua.ls Logo

Servotronix CDHD - Page 406

Servotronix CDHD
416 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Variables and Commands CDHD
406 VarCom Reference Manual
VF
Definition Velocity Loop Output Filter
Type Variable (R/W)
Description Not intended for user unless instructed by Technical
Support.
User defined velocity loop output filter.
Requires FILTMODE 6. or controller output filter in
VELCONTROLMODE 3).
Syntax Read: VF
Write: VF 1 0 0 0 0 0 0
Firmware 1.0.6
Drive status Enabled | Disabled
Range Not Applicable
Default value 1 0 0 0 0 0 0
Unit Not applicable
Non-volatile Yes
See also FILTMODE
VD
VELCONTROLMODE
VH
VR
CANopen 20D8h, sub-index 1

Table of Contents

Other manuals for Servotronix CDHD