- 8023 -
1
Signals and monitoring functions
Monitoring functions (part 2)
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
r2169
Actual speed smoothed
signals [rpm]
r2199
r2199.5
1 = Ramp-up/ramp-down completed
r2197
r2197.6
1 = |n_act| > n_max
Hysteresis speed 3
0.00 ... 300.00 [rpm]
p2150 [D] (2.00)
Torque threshold value
comparison delay time
0 ... 10000 [ms]
p2176 [D] (200)
Delay for comparison n > n_max
0 ... 10000 [ms]
p2152 [D] (200)
Delay for n_act comparison with
speed threshold value 5
0 ... 10000 [ms]
p2158 [D] (10)
0
1
0 T
0 T
0 T
T 0
T 0
T 0
0
1
Delay for n_act comparison with
speed threshold value 6
0 ... 10000 [ms]
p2160 [D] (10)
Torque threshold value 1
0.00 ... 20000000.00 [Nm]
p2174 [D] (5.13)
0
1
r2197
r2197.12
1 = |n_act| > n_max (delayed)
r2198
r2198.9
1 = |M_act| > torque threshold value 1
and n_set reached
r2198
r2198.13
1 = |M_act| > torque threshold value 1
r2198
r2198.3
1 = |n_act| > speed threshold value 6
r2198
r2198.2
1 = |n_act| <= speed threshold value 6
r2198
r2198.1
1 = |n_act| > speed threshold value 5
r2198
r2198.0
1 = |n_act| <= speed threshold value 5
Speed threshold 5
0.00 ... 210000.00 [rpm]
p2157 [D] (900.00)
Hysteresis speed 3
0.00 ... 300.00 [rpm]
p2150 [D] (2.00)
0
1
0
1
Speed threshold 6
0.00 ... 210000.00 [rpm]
p2159 [D] (900.00)
&
[2536.4]
[2536.4]
[2536.4]
[2536.4]
[2536.4]
[2536.4]
[2534.4]
[8010.3]
[6799.8]
[2537.7]
[2534.7]
r0080[0]
Torque actual value
Unsmoothed [Nm]
Figure14-218 8023 – Monitoring functions (part2)
Functions
14.11Drive functions
SINAMICS G220 converter
648 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB