- 2537 -
1
Internal control/status words
Status word, monitoring functions 3
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
Bit No. Meaning
r2199
r2199.0..11
Status word monitoring 3
r2199.41 = Speed setpoint - actual value deviation in tolerance t_on
r2199.51 = Ramp-up/ramp-down completed
r2199.61 = Current below the zero current threshold
r2199.71 = Speed deviation model/external in tolerance
01
00
02
03
05
06
07
08
10
11
12
14
13
04
09
15
r2199.01 = |n_act| < speed threshold 3
r2199.11 = f or n comparison value reached or exceeded
r2199.111 = Torque utilization < torque threshold value 2
Reserved
Reserved
[8012.1], [8023.1]
[8010.8]
[8010.8]
[8011.8]
[8011.8]
[8012.8]
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
PROFIdrive-Bit
Reserved
Figure14-222 2537 - Status word monitoring functions 3
Functions
14.11Drive functions
SINAMICS G220 converter
652 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB