Version 6.6 143 October 2014
Installation & Operation Manual 21. Software Installation and Basic Configuration
11. The configuration is copied from the Active SC board and a summary of the
settings is displayed:
Configuration Summary:
Global SC IP Address : 10.7.13.90
1
st
SC IP Address : 10.7.13.91
2
nd
SC IP Address : 10.7.13.92
Time Zone : Europe/Paris
Enable Security : 0 (no)
SC Root Password : ******
Product Type : 0 (Mediant 8000)
Note: If you install the Mediant 8000 software on both SC boards, it is possible that
copying the configuration from the Active to the Standby SC boards may fail despite
the fact that correct credentials for CLI and root users are provided. If you
experience this scenario, reboot the Active SC board at this point (by answering y to
the REBOOT now? prompt on its CLI interface), wait for 2 minutes until the Active
SC board completes the reboot and re-try copying the configuration.
12. You are prompted to start configuring. To commence the configuration, type y
and press Enter.
Start configuring ([y]/n) [n]: y
>>> Configure INET services ...
>>> Update /etc/inet/inetd.conf file ...
>>> Restore file /etc/inet/inetd.conf from the backup ...
>>> Update /etc/inet/services file ...
(This sequence is abbreviated)
13. After installation successfully completes the SC software configuration, it
determines whether OS Patches need to be installed on the specific SC board.
OS patches installation ensures that the latest operating system’s security and
stability fixes are applied. It also ensures that the Mediant 8000 software operates
in the same well-defined software environment that was used during the software
verification and validation process.
When prompted to start OS patches installation, type y and press Enter.