EAN Two Label Minimum Read ...............................................................................................................273
Addons .............................................................................................................................................................274
GTIN Enable...............................................................................................................................................................281
GS1 DataBar ..............................................................................................................................................................282
DataBar Omnidirectional Enable.......................................................................................................................282
DataBar Omnidirectional/EAN-128 Emulation...................................................................................283
DataBar Omnidirectional 2D Component Enable.............................................................................284
DataBar Omnidirectional Minimum Read............................................................................................285
DataBar Expanded Enable ...................................................................................................................................286
DataBar Expanded EAN-128 Emulation................................................................................................287
DataBar Expanded 2D Component Enable.........................................................................................288
DataBar Expanded Minimum Read ........................................................................................................289
DataBar Expanded Length Control ........................................................................................................290
DataBar Expanded Length 1.....................................................................................................................291
DataBar Expanded Length 2.....................................................................................................................292
Code 39 Enable........................................................................................................................................................293
Code 39 Start Stop Character Transmission........................................................................................294
Code 39 Check Character Calculation...................................................................................................295
Code 39 Check Character Transmission ...............................................................................................296
Code 39 Full ASCII.........................................................................................................................................297
Code 39 Minimum Read.............................................................................................................................298
Code 39 Correlation.....................................................................................................................................299
Code 39 Length Control.............................................................................................................................300
Code 39 Length 1..........................................................................................................................................301
Code 39 Length 2..........................................................................................................................................302
Code 39 Stitching .........................................................................................................................................303
Code 39 Require Margins...........................................................................................................................304
Code 32 Italian Pharmacode Enable................................................................................................................305
Code 32 Start Stop Character Transmission........................................................................................306
Code 32 Check Character Transmission ...............................................................................................307
Code 128 Enable .....................................................................................................................................................308
Code 128 Transmit Function Characters..............................................................................................309
Expand Code128 to Code 39....................................................................................................................310
Code 128 Minimum Read ..........................................................................................................................311
Code 128 Correlation ..................................................................................................................................312
Code 128 Length Control ..........................................................................................................................313
Code 128 Length 1.......................................................................................................................................314
Code 128 Length 2.......................................................................................................................................315
Code 128 Stitching.......................................................................................................................................316
EAN-128 Enable.......................................................................................................................................................317
Interleaved 2 of 5 (I 2 OF 5) Enable...................................................................................................................318
I 2 of 5 Check Character Calculation ......................................................................................................319
I 2 of 5 Check Character Transmission...................................................................................................320
I 2 of 5 Minimum Read ................................................................................................................................321
I 2 of 5 Correlation ........................................................................................................................................322
I 2 of 5 Length Control ................................................................................................................................323
I 2 of 5 Length 1.............................................................................................................................................324
I 2 of 5 Length 2.............................................................................................................................................325
I 2 of 5 Stitching.............................................................................................................................................326

Table of Contents

Other manuals for Datalogic Magellan 9800i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 9800i and is the answer not in the manual?

Datalogic Magellan 9800i Specifications

General IconGeneral
TypeBuilt-in bar code reader
Sensor type-
Scanner type1D/2D
Light levels (direct sunlight)0 - 86080 lx
Linear (1D) barcodes supportedGS1 DataBar Expanded, GS1 DataBar Omnidirectional, JAN, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Micro QR Code, QR Code, Small Aztec Code
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power source typeAC
Power consumption (standby)11 W
Power consumption (typical)12 W
Standard interfacesRS-232
Connectivity technologyWired
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Product colorBlack, Grey
Built-in displayNo
Weight and Dimensions IconWeight and Dimensions
Weight- g