EasyManua.ls Logo

Merging Pyramix - Media Management & Libraries Housekeeping; Databases

Default Icon
760 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Media Management & Libraries : Housekeeping
4 - 44
Housekeeping
The Windows hierarchical filing system can become confusing and cluttered very quickly when dealing with a
multitude of Media Files. Complex audio projects generate thousands of more or less enigmatically named files.
Keeping track of all the files used in a Project in the Windows filing system can become a nightmare even if the
user is meticulous.
Pyramix uses the concepts of Media Drives/Folders, Databases and Libraries to reduce the clutter. The Media
Management Tab, the EDL Tab, Library Tabs and Views such as; Search Results, Used Media, Media Present in
Project Default Folder and Media NOT Present in Project Default Folder, are all ways of viewing and manipu-
lating the contents of the Databases. These Media Management tools help users to work in a structured and sim-
ple manner whilst keeping track of all the Project components.
Databases
All Media listings i.e. Libraries are held in databases. A default path to all the database files can be set in Settings
> All Settings > Application > Location : Default Database Location. Otherwise the Database path will be
C:\Documents and Settings\<user name>\Application Data\Merging Technologies\Pyramix.
Important! Enough free space (several GB) must be preserved on disk for these files to grow under nor-
mal usage. If necessary, the files can be relocated to a bigger or faster drive.
Searching
Database files can be searched using a simple SQLite based search tool which is available in Library, Media Man-
ager, and View Toolbars. Search works with combinations of logical operators *, AND, OR.
Relocate Libraries
To relocate the Library Databases:
Settings > All Settings > Location : Default Database Location
Type a new location for the database files or Browse to one.
Check also that the Fade Library Location is valid:
Settings > All Settings > Application > Editing : Fade Library Location
If it isn’t valid or in the location you wish it to be, proceed as for the Database Location above.
•Click on OK
•Restart Pyramix.
Database Library paths will then be updated.
Conversion of Previous Version Libraries
The Version 7 library format is not backwards compatible, so conversion is required for libraries created in previous
Pyramix versions:
Pyramix does the conversion automatically the first time it opens any version 6 (or older) library.
Conversion will take some time, especially with large libraries, but is only required once.
A backup (.pml.6xx) is made of the original library so that it can be renamed and restored in version 6 or
previous.
The .pml file is replaced with a converted version 7 library
Note that subsequent changes made to the new version 7 .pml library will NOT be forwarded to the
backup .pml.6xx library.