Issue 4.0
SV9100 Programming Manual 1-3
SECTION 4 HOW TO EXIT PROGRAMMING MODE
To exit the programming mode:
When you are done programming, you must be out of a program option to exit
(pressing the Answer key will exit the program option).
1. Press Answer key to exit the program options, if needed.
2. Press Speaker. If changes were to the system programming, "Saving System
Data" is displayed.
3. The display shows "Complete Data Save" when completed and exits the
telephone to an idle mode.
To save a customer’s database, a blank USB Drive is required. Insert the USB
Drive into the GCD-CP10 and, using Program 90-03, save the software to the USB
Drive. (Program 90-04 is used to reload the customer data if necessary.) Note that
a USB Drive can only hold one customer database. Each database to be saved
requires a separate drive.
Password
User
Name
Level Programs at this Level
47544 necii 1 (MF)
Manufacturer (MF):
All programs
12345678 tech 2 (IN)
Installation (IN):
All programs in this section not listed below for SA and SB
0000 ADMIN1 3 (SA)
System Administrator – Level 1 (SA):
10-01, 10-02, 10-12, 10-13, 10-14, 10-15, 10-16, 10-17,
10-18, 10-22, 12-02, 12-03, 12-04, 15-01, 15-07, 15-09,
15-10, 15-11, 20-16, 21-07, 21-14, 22-04, 22-11, 25-08,
30-03, 32-02, 40-02, 41-02, 41-03, 41-04, 41-05, 41-06,
41-07, 41-08, 41-09, 41-10, 41-11, 41-12, 41-13, 41-14,
41-15, 41-16, 41-17, 41-18, 90-03, 90-04, 90-06, 90-07,
90-18, 90-19
9999 ADMIN2 4 (SB)
System Administrator – Level 2 (SB):
13-04, 13-05, 13-06
Program Mode
Base Service OP1 OP2