Issue 4.0
2-6 Program 10 : System Configuration Setup
Item
No.
Item Input Data Default
01
Terminal Type (B1)
0 = Not set
1 = Multiline Terminal
2 = SLT Adapter
3 = Bluetooth Cordless Handset (BCH)
4 = --- Not Used ---
5 = --- Not Used ---
6 = PGD(2)-U10 ADP (Paging)
7 = PGD(2)-U10 ADP (Tone Ringer)
8 = PGD(2)-U10 ADP (Door Box)
9 = PGD(2)-U10 ADP (ACI)
10 = DSS Console
11 = --- Not Used ---
0
02
Logical Port Number (B1)
0 = Not set
1 = Multiline Terminal (1~960)
2 = SLT Adapter (1~960)
3 = Bluetooth Cordless Handset (BCH) (1~960)
6 = PGD(2)-U10 ADP (Paging) (1~8)
7 = PGD(2)-U10 ADP (for Tone Ringer) (1~8)
8 = PGD(2)-U10 ADP (for Door Box) (1~8)
9 = PGD(2)-U10 ADP (for ACI) (1~96)
10 = DSS (1~32)
11 = --- Not Used ---
0
03
Additional Data
0 = No Setting
3 = BCH: 01 ~16
0
04
--- Not Used ---
05
--- Not Used ---
B-Channel 2
Item
No.
Item Input Data Default
06
Terminal Type (B2)
0 = Not set
6 = PGD(2)-U10 ADP (Paging)
7 = PGD(2)-U10 ADP (Tone Ringer)
8 = PGD(2)-U10 ADP (Door Box)
9 = PGD(2)-U10 ADP (ACI)
12 = APR (B2 Mode)
0