SV9100 Programming Manual 2-7
For LCA PKG Setup
07
Logical Port Number (B2)
0 = Not set
6 = PGD(2)-U10 ADP (Ext. Speaker)
7 = PGD(2)-U10 ADP (Paging/Tone Ringer)
= (1~8)
8 = PGD(2)-U10 ADP (for Door Box) = (1~8)
9 = PGD(2)-U10 ADP (ACI) = (1~96)
12 = APR (for B2 mode) (193~512)
0
08
Multiline Telephone Type
0 = DT3**
1 = D
term
8
2 = D
term
7
0
09
Side Option Information
0 = No option
1 = 8LK Unit
2 = 16LK Unit
3 = 24ADM
0
10
Bottom Option Information
(Only applies to DTL–style
telephones)
0 = No option
1 = APR
2 = ADA
3 = BHA
4 = ---Not Used ---
5 = BCA
0
11
Handset Option
Information
0 = No option
1 = PSA/PSD
2 = Bluetooth Cordless Handset (BCH)
0
Input Data
Physical Port Number 01~16
Item
No.
Item Input Data Default
01
Logical Port Number
0~960 0
03
Transmit Gain Level (S-Level)
1~57 (-15.5 +12.5dB) 32 (0dB)
04
Receive Gain Level (R-Level)
1~57 (-15.5 +12.5dB) 32 (0dB)
B-Channel 2
Item
No.
Item Input Data Default