Issue 4.0
SV9100 Programming Manual 2-9
For DIOP PKG Setup
For BRIA PKG Setup
Input Data
Physical Port Number 01~04
Item
No.
Item Input Data Default
01
LD/OPX Specification
0 = LD Trunk
1 = OPX
0
02
Logical Port Number
0 = 1~400 (LD Trunk)
1 = 1~960 (OPX)
0
Input Data
ISDN Line Number 01~04
Item
No
Item Input Data Default
01
ISDN Line Mode
0 = Not Used
1 = T-Point
2 = S-Point (Not used)
3 = NW Mode (Leased Line)
4 = NW Mode (Interconnected Line)
5 = NW Mode (Interconnected Line,
Fixed Layer1 = NT)
6 = S-Point (Leased Line) (Not used)
1
02
Logical Port Number
The starting port number of
a BRI line is displayed. Two logic
ports are automatically assigned to
a BRI line.
0 = Not Used
1 = T-Point (1~400)
2 = S-Point (1~960) (Not used)
3 = NW Mode (Leased Line) (1~256)
4 = NW Mode (Interconnected Line)
(1~256)
5 = NW Mode (Interconnected Line,
Fixed Layer1 = NT) (1~256)
6 = S-Point (Leased Line) (1~960)
(Not used)
0
03
Connection Type
0 = Point-to-Multipoint
1 = Point-to-Point
0