Issue 4.0
2-826 Program 90 : Maintenance Program
6 0 0 Blocking The link of terminals
connected with the ESI
package came off.
1. Terminal
breakdown.
2 Faulty wiring and
wiring
termination.
3. External noise.
4. ESI package
Breakdown.
1. Confirm the terminal
connected with
same ESI. If they
work normally,
confirm the
breakdown or the
wiring for the
terminal.
2. Exchange the
terminal that doesn't
work and the
working terminal,
and confirm it’s
working. An external
factor of the noise
etc. is thought.
3. Confirm wiring and
the installation,etc.
4.Check with
manufacturer if the
problem occurs
again.
The error is
recovered
when
connecting or
exchanging it.
ERR
REC
7 1 0 Power failure The supply of the
commercial power
stopped.
1. The power cable
came off.
2. Power failure
3. The power
supply broke
down.
1. Confirm the power
supply outlet when
the commercial
power has not
stopped.
2. Check with the
manufacturer if the
problem occurs
again.
When the
commercial
power is
restored, the
error is
recovered.
ERR
REC
8 1 0 RAM Backup
Battery Error
RAM backup battery on the
GCD-CP10 blade is
unplugged or defective.
Check the battery
connector. If it is
connected correctly,
replace the battery.
The error is
recovered
once the
battery is
replaced.
ERR
REC
9 --- Reserved ---
10 0 0 ISDN Link
Error
Layer1 link of ISDN lines
came off.
1. Check
connection
between main
device and ISDN
line.
2. DSU breakdown
3. The setting of
PRG10-03 does
not correspond
to an actual line.
1. Confirm the data of
PRG10-03.
2. Confirm wiring and
installation of DSU.
3. Check with the
manufacturer if the
problem occurs
again.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
11 0 0 CTI Link Error The link with the CTI server
came off.
1. LAN cable
defective.
2. Connected HUB
broken.
3. The CTI server
doesn't start
normally.
1. Confirm the CTI
server, wiring, and
the connection.
2. Check with
manufacturer if the
problem occurs
again.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
Alarm
No.
Type Report Name Content of Alarm Cause Action Recovery
Alarm