EasyManua.ls Logo

NEC Univerge SV9100 - Page 869

NEC Univerge SV9100
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 4.0
SV9100 Programming Manual 2-829
36 0 0 CS error
notification 1
CS detected the problem
occurring in the air
synchronous signal
between CS-CSIU, BBIC
reset was executed, and it
was restored automatically.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
37 0 0CS
transmission
error.
Because CS had not
returned the response to
the control signal from a
main device longer than
the fixed time, it was
restored automatically
specifying reset to
concerned CS with a main
device.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
38 0 0CSIU Dch
Error×
It was restored
automatically specifying
reset to concerned CS with
a main device because a
main device had detected
the control signal from a
main device not normally
reaching CS.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
39 0 0CSIU trans-
mission error.
This alarm is integrated
into Communication fault
between the GCD-CP10
and other PKG, and it is not
used in SV9100.
Alarm
No.
Type Report Name Content of Alarm Cause Action Recovery
Alarm
Status

Table of Contents

Other manuals for NEC Univerge SV9100

Related product manuals