Issue 4.0
2-828 Program 90 : Maintenance Program
29 0 0 Charge
Management
Buffer full
The temporary buffer for
the charge management in
main device overflowed,
and a part of unoutput
charge data disappeared
because it could not output
the charge management
data.
1. The charge data
is printed and
not deleted at
the simple
charge
management.
2. The charge data
is not output to
PC for the
charge
management
software.
1. Print and delete the
charge data at the
simple charge
management.
2. Connect the charge
management
software for the
charge management
software and output
the charge data.
When the
output is
restarted, the
error is
recovered.
However, the
charge
management
data after the
error occurs is
not recorded.
ERR
REC
30 2 0SMDR Buffer
full
The temporary buffer for
SMDR in main device
overflowed, and a part of
unoutput SMDR data
disappeared because it
could not output SMDR
data.
1. Problem of
wiring to
connect main
device with PC.
2. PC Problem.
1. Confirm whether
there is problem in
wiring to connect a
main device with
PC.
2. Execute the
reactivation of PC.
When the
output is
restarted, the
error is
recovered.
However, the
SMDR data
after the error
occurs is not
recorded.
ERR
REC
31 1 0 Auto Dial after
Sensor
Detection
Auto dialing occurs after
sensor detection.
Sensor detect an
abnormality and
makes an
emergency call.
No action needed.
32 1 0 Remote
watch
function
performs auto
dial.
Remote watch function
performs auto dial.
No action needed/
33 1 0 Fail to auto
dial by
security
function.
Fail to auto dial by security
function.
All auto dial trunks
are busy.
No action needed.
34 --- Reserved ---
35 0 0 CS Blocking The link of the CSIU and
CS came off.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1 Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
The error is
recovered
when
reconnecting
or exchanging
it.
ERR
REC
Alarm
No.
Type Report Name Content of Alarm Cause Action Recovery