EasyManua.ls Logo

Ford 2002 Bantam - The Heater Blower System Is Inoperative

Ford 2002 Bantam
1663 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
412-00-20 Climate Control System — General Information 412-00-20
DIAGNOSIS AND TESTING (CONTINUED)
CONDITIONS
DETAILS/RESULTS/ACTIONS
B23: CHECK THE CIRCUIT 31S-CA12 (BK/BU) FOR OPEN
1 Measure the resistance between A/C
compressor cycling switch, connector C91, pin
1, circuit 31S-CA17 (BK/RD), harness side and
dual pressure switch, connector C77, pin 2,
circuit 31S-CA12 (BK/BU), harness side.
• Is the resistance less than 2 ohms?
 Yes
GO TO B24
 No
REPAIR the open circuit(s) between dual
pressure switch and PCM by using the wir-
ing diagrams. TEST the system for normal
operation.
B24: CHECK THE A/C INHIBIT DIODE
1 Check the A/C inhibit diode referring to the
diode test.
• Is the A/C diode OK?
 Yes
REPAIR the open circuit(s) between dual
pressure switch and relay – A/C switch by
using the wiring diagrams. TEST the system
for normal operation.
 No
INSTALL a new A/C inhibit diode. TEST the
system for normal operation.
PINPOINT TEST C: THE HEATER BLOWER SYSTEM IS INOPERATIVE
CONDITIONS
DETAILS/RESULTS/ACTIONS
C1: DETERMINE THE FAULT CONDITION
1.
2 Turn the heater blower switch from SLOW
SPEED to HIGH SPEED position.
3 Check the airflow.
• Is the heater blower in all positions
inoperative?
 Yes
GO TO C2
 No
GO TO C8
E9425 EN 07/2001 2002 Bantam

Table of Contents

Related product manuals