100-04-54 Noise, Vibration and Harshness 100-04-54
GENERAL PROCEDURES
E4449 EN 02/2001 2002 Bantam
Powertrain/Drive train Mount Neutralizing (14 001 0)
1. NOTE: An abnormal vibration can be caused
by a component, such as an engine or
transaxle support insulator mount, which is
acting in a rigid manner because of a
distorted or twisted mounting position. As a
result, the support insulator does not absorb
vibration, as it should.
Loosen the engine insulator mounting bolts
by three turns.
2. Start the engine and shift into drive.
3. While the tires are in contact with the
ground, rock the vehicle back and forth.
4. Shift back into neutral and shut off the
engine. Retighten the engine insulator
mounting bolts.