412-00-48 Climate Control System — General Information 412-00-48
GENERAL PROCEDURES
Air Conditioning (A/C) System Evacuation and Charging (34 620 2)
General Equipment
Service unit
WARNING: Observe "Health and Safety
Rules". For additional information,
refer to Section 100-00
.
CAUTION: The refrigerant detector must
be used before evacuation; otherwise,
the service unit may become contami-
nated. Contaminated refrigerant must be
disposed of as hazardous waste. Al-
ways follow the manufacturer instruc-
tions when using the service units.
1. Remove the protective caps of the filler
valves and connect the service unit leads to
the filler valves.
Pull back the lock on the quick-release
connector.
1. Larger inside diameter for high-pressure
side.
2. Smaller inside diameter for low-pressure
side.
2.
WARNING: Avoid releasing the
refrigerant into the atmosphere at all
costs.
Drain the air conditioning system through
the low-pressure port in accordance with
the service unit manufacturer instructions.
3. NOTE: The air conditioning system has to be
evacuated for approximately 30 minutes in
order to make sure that the system will work
perfectly again once refilled.
NOTE: If moisture has entered the open system
over an extended period of time (several hours),
install a new accumulator / dryer and extend the
evacuation time to 2-3 hours.
Evacuate the air conditioning system in
accordance with the service unit
manufacturer instructions.