EasyManua.ls Logo

Ford 2002 Bantam - Unusual Starter Motor Noise

Ford 2002 Bantam
1663 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
303-06-209 Starting System 303-06-209
DIAGNOSIS AND TESTING (CONTINUED)
E1017 EN 09/2001 2002 Bantam
CONDITIONS
DETAILS/RESULTS/ACTIONS
B2: CHECK THE SUPPLY TO STARTER
1.
2 Measure the voltage between the starter
terminal B, circuit 30 (RD) and ground.
• Is the voltage greater than 12.5 volts?
 Yes
GO TO B3
 No
REPAIR circuit 30 (RD). TEST the system
for normal operation.
B3: CHECK THE STARTER GROUND CIRCUIT
1 Measure the resistance between the starter
motor casing and negative (-) battery terminal.
• Is the resistance less than 5 ohms?
 Yes
INSTALL a new starter motor. TEST the
system for normal operation.
 No
CLEAN and REPAIR grounds as required.
TEST the system for normal operation.
PINPOINT TEST C: UNUSUAL STARTER MOTOR NOISE
CONDITIONS
DETAILS/RESULTS/ACTIONS
C1: CHECK THE STARTER MOUNTING
1 Check the starter and mounting brackets for
correct alignment.
• Is the starter mounted correctly?
 Yes
GO TO C2
 No
INSTALL the starter motor.
Refer to the procedure in this section.
TEST the system for normal operation.

Table of Contents