414-00-6 Charging System — General Information 414-00-6
DIAGNOSIS AND TESTING (CONTINUED)
CONDITIONS
DETAILS/RESULTS/ACTIONS
3 Measure the resistance between the
instrument cluster C44b pin 7, circuit 64 (BU-
BK) and ground.
• Is the resistance greater than 10,000 ohms?
Yes
INSTALL a new printed circuit board.
No
REPAIR circuit 64 (BU-BK). TEST the sys-
tem for normal operation.
A4: CHECK FOR VOLTAGE
1.
Generator
(C303a)
2.
3 Measure the voltage between the generator
connector C303a pin 1, circuit 31 (BK) and
ground.
• Is the voltage greater than 10 volts?
Yes
INSTALL a new generator.
No
GO TO A2
PINPOINT TEST B: THE CHARGING SYSTEM WARNING INDICATOR IS INOPERATIVE
CONDITIONS
DETAILS/RESULTS/ACTIONS
B1: CHECK LAMP CIRCUIT
1.
Generator
(C303a)
2.