414-00-7 Charging System — General Information 414-00-7
DIAGNOSIS AND TESTING (CONTINUED)
CONDITIONS
DETAILS/RESULTS/ACTIONS
3 Measure the voltage between generator D+
connector C303a pin 1, circuit 31 (BK) and
ground.
• Is the voltage greater than 10 volts?
Yes
GO TO B2
No
GO TO B3
B2: CHECK BULB
1 Connect a jumper wire between the generator
D+ connector C303a pin 1, circuit 31 (BK) and
ground.
• Does the lamp illuminate?
Yes
INSTALL a new generator. TEST the
system for normal operation.
No
INSTALL a new bulb. TEST the system for
normal operation.
B3: CHECK CIRCUIT 64- A1 (BU) D
1.
C1
2 Measure the voltage between in-line connector
C1 pin 3 circuit 64 (BU) and ground.
• Is the voltage greater than 10 volts?
Yes
REPAIR circuit 31 (BK). TEST the system
for normal operation.
No
REPAIR circuit 64. TEST the system for
normal operation.
E1297 EN 07/2001 2002 Bantam