412-00-27 Climate Control System — General Information 412-00-27
DIAGNOSIS AND TESTING (CONTINUED)
CONDITIONS
DETAILS/RESULTS/ACTIONS
D2: CHECK THE POWER SUPPLY OF THE FUSE F16
1.
Fuse F16 (CJB)
2.
3 Measure the voltage between fuse F16 and
ground.
• Is battery voltage indicated?
Yes
GO TO D3
No
REPAIR the power supply of the fuse F16
by using the wiring diagrams. TEST the sys-
tem for normal operation.
D3: CHECK THE FUSE F13
1.
2.
Fuse F13 (CJB)
• Is the fuse OK?
Yes
GO TO D4
No
INSTALL a new fuse F13 (15 A). If the fuse
blows again, LOCATE and REPAIR the
short to ground of the circuit(s) by using the
wiring diagrams. TEST the system for nor-
mal operation.
D4: CHECK THE POWER SUPPLY OF THE FUSE F13
1.
Fuse F13 (CJB)
2.
3 Measure the voltage between fuse F13 and
ground.
• Is battery voltage indicated?
Yes
GO TO D5
No
REPAIR the power supply of the fuse F13
by using the wiring diagrams. TEST the sys-
tem for normal operation.
E9425 EN 07/2001 2002 Bantam