412-03-15 Air Conditioning 412-03-15
REMOVAL AND INSTALLATION (CONTINUED)
8. Pull off the connector and detach the
coolant hoses.
1. Separate the electrical connector of the
heater control valve.
2. Undo the clamps and detach the coolant
hoses.
9. Remove the heater cover.
• Remove the four bolts.
10. Pull out the evaporator (push fit).
Installation
NOTE: Before connecting the refrigerant lines,
fit them with new O-rings. Coat the new O-rings
with refrigerant oil before fitting them.
1. Refit the components in the reverse order.
2. Drain and refill the air conditioning system.
For additional information,
refer to Section
412-00.
E1257 EN 07/2001 2002 Bantam