413-01-9B Instrument Cluster 413-01-9B
DIAGNOSIS AND TESTING (CONTINUED)
CONDITIONS
DETAILS/RESULTS/ACTIONS
A2: VERIFY FAULT OF FUEL GAUGE
1.
• Does the fuel gauge pointer indicate below the
empty (default position)?
Yes
GO TO A3
No
GO TO A6
A3: TEST FOR VALID INPUT FROM THE FUEL PUMP MODULE
1 Select the Instrument cluster self-diagnostic
mode test 10 – fuel volume input test.
• Is the value F010 or less?
Yes
GO TO A4
No
If the value is between F011 and F254
GO TO A6
If the value is F255 GO TO A7
A4: TEST FOR SHORT TO GROUND ON FUEL PUMP MODULE UNIT
1.
Fuel Pump Mod-
ule C88
2 Leave the instrument cluster in self-diagnostic
mode test 10 – fuel volume input test.
• Does the fuel input value change to F255 when
the fuel pump module is disconnected?
Yes
INSTALL a new fuel pump module. TEST
the system for normal operation.
No
GO TO A5
A5: TEST CIRCUIT 8-GA7 (WH/RD) FOR SHORT TO GROUND
1.
2.
Instrument Cluster
C39
E1282 EN 09/2001 2002 Bantam