1-6
dropevents : 0 , octets : 0
packets : 0 , broadcast packets : 0
multicast packets : 0 , CRC alignment errors : 0
undersize packets : 0 , oversize packets : 0
fragments : 0 , jabbers : 0
collisions : 0 , utilization : 0
Sampled values of record 4 :
dropevents : 0 , octets : 0
packets : 0 , broadcast packets : 0
multicast packets : 0 , CRC alignment errors : 0
undersize packets : 0 , oversize packets : 0
fragments : 0 , jabbers : 0
collisions : 0 , utilization : 0
Sampled values of record 5 :
dropevents : 0 , octets : 0
packets : 0 , broadcast packets : 0
multicast packets : 0 , CRC alignment errors : 0
undersize packets : 0 , oversize packets : 0
fragments : 0 , jabbers : 0
collisions : 0 , utilization : 0
Table 1-4 display rmon history command output description
Field Description
HistoryControlEntry
History control entry, corresponding to the MIB node
etherHistoryIndex.
owned by
Owner of the entry, corresponding to the MIB node
historyControlOwner.
VALID
Status of the entry identified by the index (VALID means
the entry is valid, and UNDERCREATION means
invalid. You can use the display rmon command to
view the invalid entry; while with the display
current-configuration and display this commands
you cannot view the corresponding rmon commands.),
corresponding to the MIB node historyControlStatus.
Samples Interface The sampled interface
Sampling interval
Sampling period, in seconds, corresponding to the MIB
node historyControlInterval. The system samples the
information of an interface periodically.
buckets max
The maximum number of history table entries that can
be saved, corresponding to the MIB node
historyControlBucketsGranted.
If the specified value of the buckets argument exceeds
the history table size supported by the device, the
supported history table size is displayed.
If the current number of the entries in the table has
reached the maximum number, the system will delete
the earliest entry to save the latest one.
Sampled values of record number
The (number)th statistics recorded in the system cache.
Statistics records are numbered according to the order
of time they are saved into the cache.

Table of Contents

Other manuals for H3C S5120-SI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5120-SI Series and is the answer not in the manual?

H3C S5120-SI Series Specifications

General IconGeneral
BrandH3C
ModelS5120-SI Series
CategorySwitch
LanguageEnglish

Related product manuals