EasyManua.ls Logo

Hirschmann RS20

Hirschmann RS20
572 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands: Base
104
4.6
Management Commands
CLI L2P
Release
7.0
05/2011
refresh-interval
This command configures the digital inputs refresh interval. Each
input configured for event logging or SNMP traps is polled with this
interval.
<refresh-interval> The refresh interval is in the range of 1..10
seconds. Default: 1.
log-event
This command enables or disables the event logging of input status
changes for one or all digital inputs. Default: disable.
The input state will be checked according to the interval set with IO-
<refresh-interval>.
all Configure the IO-Module event logging for all digital inputs.
<slot/input> Configure the IO-Module event logging for a single
digital input.
disable Disable event logging for digital input status changes.
enable Enable event logging for digital input status changes.
snmp-trap
This command enables or disables the sending of SNMP traps in
case of input status changes for one or all digital inputs. Default:
disable.
The trap will be sent to all SNMP trap receivers configured with
snmptrap.
The input state will be checked according to the interval set with IO-
<refresh-interval>.
all Configure the IO-Module SNMP trap for all digital inputs.
<slot/input> Configure the IO-Module SNMP trap for a single
digital input.
disable Disable SNMP traps for digital input status changes.
enable Enable SNMP traps for digital input status changes.