300
4.11
System Utilities
CLI L2P
Release
7.0
05/2011
trap
Configures the sending of traps concerning the signal contact.
– enable enables sending traps,
– disable disables sending traps.
4.11.26temperature
This command configures the lower and upper temperature limit for the
device. If these limits are exceeded, a trap is sent. The unit for the
temperature limit is °C (Celsius), the minimum value is -99, the maximum
value is 99. The default for the lower limit is 0, for the upper limit, it is 70.
Note: To give the temperature in Fahrenheit, use the suffix f.
Note: The command is available for RS20/RS30/RS40, MS20/MS30,
RSR20/RSR30, MACH100, MACH 1000, PowerMICE, MACH 4000 and
OCTOPUS devices.
Format
temperature {lower-limit|upper-limit} <temperature
value> [c|f]
Mode
Global Config
lower-limit
Configure the lower temperature limit.
upper-limit
Configure the upper temperature limit.