CLI Commands: Switching
424
5.1
Spanning Tree Commands
CLI L2P
Release
7.0
05/2011
5.1.25 spanning-tree mst priority
This command sets the bridge priority for a specific multiple spanning tree in-
stance. The instance <mstid> is a number that corresponds to the desired ex-
isting multiple spanning tree instance. The priority value is a number within a
range of 0 to 61440 in increments of 4096.
This command accepts the value 0 for the mstid.
If 0 (defined as the default CIST ID) is passed as the <mstid>, then this
command sets the Bridge Priority parameter to a new value for the common
and internal spanning tree. The bridge priority value again is a number within
a range of 0 to 61440. The twelve least significant bits will be masked
according to the 802.1s specification. This will cause the priority to be
rounded down to the next lower valid priority.
Default
32768
Format
spanning-tree mst priority <mstid> <0-61440>
Mode
Global Config
U no spanning-tree mst priority
This command sets the bridge priority for a specific multiple spanning
tree instance to the default value, i.e. 32768. The instance <mstid> is a
number that corresponds to the desired existing multiple spanning tree
instance.
This command accepts the value 0 for the mstid.
If 0 (defined as the default CIST ID) is passed as the <mstid>, then this
command sets the Bridge Priority parameter for the common and internal
spanning tree to the default value, i.e. 32768.
Format
spanning-tree mst priority <mstid>
Mode
Global Config

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16