CLI Commands: Switching
458
5.5
Redundant Coupling
CLI L2P
Release
7.0
05/2011
5.5.4 ring-coupling net-coupling
Coupling mode refers to the type of coupled network.
Possible values are:
D network ,if you wish to couple a line-type configuration.
D ring-only ,if you wish to couple a HIPER-Ring.
Default
none
Format
ring-coupling net-coupling <{network|ring-only}>
Mode
Global Config
5.5.5 ring-coupling operation
Configure the Ring Coupling's operation setting. Possible values are:
D on Enable the current Ring Coupling configuration.
D off Disable the current Ring Coupling configuration.
Default
off
Format
ring-coupling operation <{off|on}>
Mode
Global Config