390
4.17
Port monitor
CLI L2P
Release
7.0
05/2011
4.17.10port-monitor condition crc-fragment (Global
Config)
Use this command to configure the crc-fragment settings (crc-fragment
counter and interval for crc-fragment detection).
Default
Disable
Format
port-monitor condition crc-fragment
{count <1-1000000> | interval <5-180>}
Mode
Global Config
count
Configure the crc-fragment counter.
Default: 1,000. Value range: 1 - 1,000,000.
interval
Configure the measure interval in seconds for crc-fragment detection.
Default: 10 seconds. Value range: 5 - 180 seconds.