CLI Commands: Switching
490
5.9
Sub-Ring Commands
CLI L2P
Release
7.0
05/2011
5.9.9 sub-ring delete-ring
Delete all existing Sub-Rings IDs or a specific Sub-Ring ID.
Format
sub-ring delete-ring {all-ids | <id>}
Mode
Global Config
all-ids
Delete all existing Sub-Ring IDs.
<id>
Delete the given Sub-Ring ID. Format: a number in the range
1-2147483647 (2
31
- 1). An ID of 0 is invalid.
5.9.10 sub-ring new-ring
Create a new Sub-Ring ID. The configuration will consist of default
parameters and its operation will be disabled.
Format
sub-ring new-ring <id>
Mode
Global Config
<id>
Enter a new Sub-Ring ID. Format: a number in the range
1-2147483647 (2
31
- 1). An ID of 0 is invalid.