296
4.11
System Utilities
CLI L2P
Release
7.0
05/2011
4.11.20device-status connection-error
This command configures the device status link error monitoring for this port.
Default
ignore
Format
device-status connection-error {ignore|propagate}
Mode
Interface Config
4.11.21device-status monitor
This command configures the device-status.
Format
device-status monitor
{aca-removal | all | connection-error |
hiper-ring |
module-removal | power-supply-1 |
power-supply-2 | power-supply-3-1 |
power-supply-3-2 |power-supply-4-1 |
power-supply-4-2 | ring-coupling | temperature }
{error|ignore}
device-status trap {disable|enable}
Mode
Global Config
monitor
Determines the monitoring of the selected event or all events.
error If the given event signals an error, the device state will also
signal error,
ignore Ignore the given event - even if it signals an error, the
device state will not signal 'error' because of that.